Vane pump PV2R1-23-F-RAA-40 explanation

2025-06-16

1. Model analysis and technical parameters

PV2R1-23-F-RAA-40

Series:PV2R1 (single vane pump, compact design)

Displacement: 22.7 cm³/rev (single vane pump theoretical displacement)

Mounting method: F (flange mounting)

Rotation direction: R (clockwise standard)

Discharge port direction: A (upward standard)

Suction port direction: A (upward standard)

Technical parameters:

Rated pressure: 210 kgf/cm²

Maximum speed: 1800 rpm

2. Application Scenarios and Advantages

PV2R1-23-F-RAA-40

Typical applications:

Injection molding machine auxiliary circuit: driving mold opening and closing, ejector movement, and low flow demand conditions.

Light machine tools: providing stable power for tool feeding and worktable movement.

Advantages:

Compact structure: suitable for equipment with limited installation space.

Low noise: optimized blade design to reduce operating noise.

3. Selection and maintenance guide

(1)Selection points

Displacement matching: Select the displacement according to the maximum flow demand of the system to avoid too large or too small displacement.

Pressure requirement: Confirm the maximum pressure of the system and select a pump with sufficient pressure resistance.

Installation method: Select flange installation (F) or foot installation according to the equipment space.

Interface direction: The RAA mark corresponds to the oil port position, which needs to be confirmed in conjunction with the hydraulic diagram.

(2) Maintenance recommendations

Oil cleaning: Regularly replace hydraulic oil and clean the oil filter to prevent contamination.

Temperature control: Avoid excessive oil temperature and install a cooler if necessary.

Pressure monitoring: Install a pressure gauge to monitor system pressure in real time.

Seal inspection: Regularly check the shaft seal and O-ring and replace them immediately if leakage is found.

4. Common Problems and Solutions

(1)Insufficient pressure

Reason: internal wear of hydraulic pump, overflow valve failure, low oil viscosity.

Solution: Check and repair worn parts, adjust or replace overflow valve, and replace oil with appropriate viscosity.

(2)Excessive noise

Reason: loose installation, non-concentric coupling, oil suction pipe blockage, air in the oil.

Solution: Reinstall and fix, adjust the coupling, clean the oil suction pipe, and remove the air.

(3)Unstable flow

Reason: Blade wear, stator curve wear, oil contamination.

Solution: Replace worn blades or stators, clean or replace oil.

4. Summary and Recommendation

PV2R1-23-F-RAA-40 is a cost-effective vane pump launched by He Hydraulics for small and medium-sized hydraulic systems. It takes into account both performance and reliability and is suitable for users who are sensitive to space, noise and cost.


Get the latest price? We'll respond as soon as possible(within 12 hours)