AR22-FR01B-22 Yuken-Type Replacement Piston Pump
Request a YHDE replacement pressure-compensated, variable-displacement piston pump for the installed AR22-FR01B-22. Send the complete nameplate, cut-off setting, duty and installation details so the proposed pump can be checked against your machine.
Original reference and offered pump are separate. Verify the exact design -22, pressure-adjustment range, ports, drain, shaft and mounting against the offered drawing and supplier data before approving interchangeability.
Model Code and Selection
| Code | Identification reference |
|---|---|
| AR22 | AR-series variable piston pump; original AR22 reference maximum geometric displacement 22.2 cm³/rev. |
| F / R | Flange mounting / clockwise rotation viewed from the shaft end. |
| 01 / B | Pressure compensator / B adjustment range. The cited original older AR catalogue gives 1.5–7 MPa full cut-off; verify the actual -22 version and supplied unit. |
| No S / 22 | Standard port-position designation in the cited original model scheme / design number 22. Do not drop S, design-standard numbers or other suffixes from the nameplate. |
B and C control ranges, AR16 and AR22 displacement, and alternative port positions are distinct selection choices. Do not replace one with another without engineering approval. Design compatibility and spare-part fit must be confirmed for the offered unit.
Pressure, Displacement and Operating Point
The original Yuken catalogue for older AR22 -20 variants lists 22.2 cm³/rev, 600–1800 rpm and 16 MPa rated pressure. Its B compensator adjustment range is 1.5–7 MPa (15–70 bar) full cut-off. A Yuken USA listing identifies the -22 B version as approximately 170–1020 psi; confirm exact adjustment limits and settings in the correct -22 documentation and with the supplier.
Do not confuse assembly pressure rating with the B compensator setting. A 16 MPa frame reference does not mean an 01B control is adjustable to 16 MPa. The original -20 reference lists 21 MPa intermittent with short-duration and cycle restrictions; it is not permission to set the B pump to 21 MPa or a verified rating for the offered -22 replacement.
At maximum displacement, ideal flow Q = Vg × n / 1000 gives 33.3 L/min at 1500 rpm or 39.96 L/min at 1800 rpm. Actual delivery falls with leakage and as the compensator reduces displacement. Confirm the required loaded flow, actual setting, cycle and motor power; pressure compensation is not a guaranteed percentage of energy savings.
Installation and Case Drain
Match flange pilot, mounting holes, shaft diameter/key and coupling engagement against the correct -22 drawing. Record port arrangement, thread standard and suction, discharge and case-drain connections.
Confirm rotation viewed from the shaft end, fluid type, temperature, viscosity, filtration and suction condition. Arrange the case drain and reservoir connection in accordance with the pump manufacturer’s instructions; avoid excessive case pressure.
Before initial start, fill the pump case with clean compatible oil through the specified filling port. Follow the supplied procedure for air removal, unloaded startup and progressive commissioning.
Pressure and flow adjustment must be performed by qualified personnel using gauges and the equipment instructions. Confirm relief valve and full cut-off settings without exceeding the applicable limits.
Diagnosis, Repair and Parts
Low flow, heat or unstable pressure may arise from suction restriction, aeration, oil condition, compensator adjustment, relief leakage or internal wear. Record operating speed, pressure, loaded flow, case-drain flow and oil temperature before deciding on repair.
For replacement components provide the complete pump designation, manufacturer, design standard, available part numbers and photographs; inspect the rotating group, valve plate, shaft and housing. Availability and included parts require confirmation; a complete rotating group or nine-piston configuration is not assumed. After a failure, assess contamination in the tank, filters, hoses and valves.
A22 piston pump selection — a different series; compare specifications before considering substitution.
Prepare an AR22 Inquiry
Enter known information and select a request; review the message, add your email and submit manually.
Preparing a message does not send an inquiry.
The existing form has no attachment field. Describe available nameplate, drain and mounting photos or drawings and ask how to send them. Ask for the offered model, drawing, B-range and operating limits, price and dispatch estimate. If unavailable, use the contact page.
AR22 Questions
What does the B mean?
It identifies a pressure adjustment range in the original model code. The older original AR reference gives 1.5–7 MPa full cut-off; confirm the specific design and supplied pump.
Does 16 MPa mean the B compensator can be set to 16 MPa?
No. A family assembly pressure rating and the B adjustment range are different. Verify the exact setting and offered model.
Does the pump always deliver 22.2 L/min?
No. 22.2 cm³/rev is the maximum geometric displacement reference, not flow. Flow depends on speed, adjusted displacement, pressure and losses.
Can I substitute AR16 or a C-control pump?
They differ in displacement or pressure range. Review the duty, mounting and controls with the supplier before any substitution.
What is needed for a repair quotation?
Send the full nameplate, manufacturer, symptoms, measured conditions, affected parts and available photographs or drawings.
Yuken Reference Documents
Yuken AR series catalogue, older -20 design · Yuken USA AR22-FR01B-22 product reference. Confirm the supplied replacement and correct edition.