• PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE
  • PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE
  • PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE
  • PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE
  • PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE

PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE

Brand: YiHe

Product origin: China

Delivery time: 10-30days

Supply capacity: 300pcs/day

High-pressure PV2H23-26-94 double hydraulic vane pump, 100% interchangeable with Yuken PV2H series. Supports up to 31.5 MPa. Factory-direct from YHDE with 9+ years of expertise. Dual-flow efficiency for industrial machinery. Get a quote!

Download:

PV2H23-26-94 Double Vane Pump | 100% Yuken Type Replacement | YHDE

Drowning in 16-Week OEM Lead Times for a Yuken PV2H23 Double Pump? Restore Full Power in 48 Hours!

When a heavy-duty high-pressure double vane pump loses pressure, develops internal bypass leakage, or suffers housing wear in your Sumitomo, Toshiba, or Nissei plastic injection molding machinery, die-casting press, or industrial hydraulic station, waiting 12 to 20 weeks for expensive original Japanese imports severely burns your daily workshop profitability.

Our premium Yuken Compatible PV2H23-26-94-F-REAA-41 High-Pressure Double Hydraulic Vane Pump offers an absolute 100% "drop-in" mechanical replacement solution. Engineered in our ISO-compliant direct factory with 9+ years of micro-tolerance hydraulic tooling mastery, this whisper-quiet dual-discharge pump restores original volumetric flow speeds,<68 dB noise control, and 21 MPa pressure thresholds—slashing your procurement and MRO maintenance budget by up to 70%.

  • 100% Physical Form Match: Standard JIS/SAE mounting flanges, drive shaft keys, port configurations, and bolt holes match original Yuken specs identically. Install instantly with zero pipe re-routing.

  • Direct Factory Stocking: Pre-assembled from component reserves, dynamically full-load bench tested to 21 MPa across both chambers, and shipped worldwide within 24-48 hours.

Technical Specifications & Operational Parameters

Cross-verify your equipment's operating pressure curves, required flow rates, and mounting envelopes using our master engineering data table below:

Parameter AttributeFront Pump Section (PV2H2 Shaft End)Rear Pump Section (PV2H3 Cover End)Application System Advantage
Nominal Displacement Flow26.0 cm³/rev (ml/r Code 26)94.0 cm³/rev (ml/r Code 94)Total 120 cm³/rev combined flow for high-low rapid advance and holding loops.
Max Operating Pressure21.0 MPa (210 bar / 3045 PSI)21.0 MPa (210 bar / 3045 PSI)Heavy ductile iron casting eliminates body flexing under severe pressure surges.
Operating Speed Range600 - 1800 r/min (RPM)600 - 1800 r/min (RPM)Standard speed limits compatible with industrial electric prime movers.
Average Operational NoiseStrictly Under 68 dB(A) at Full PressureCircular arc vane profile dampens fluid pulsation for quiet workshops.

Model Ordering Nomenclature Decoded: PV2H23-26-94-F-REAA-41

Code SegmentTechnical Specifications MeaningSystem Installation Alignment Reference
PV2H23High-Pressure Double Vane Pump Series Frame (PV2H2 + PV2H3 Heavy Cartridges)Integrates dual "2" and "3" size pump cartridges inside a single heavy casting.
26 / 94Displacement Codes (Front: 26 ml/r / Rear: 94 ml/r)Sets the precise continuous volumetric flow rates for dual high-volume circuits.
FMounting Style: Flange Type ConfigurationDirectly matches original standard SAE/Japanese flange coupling alignments.
RDirection of Shaft Rotation: Clockwise (CW) PathMust align with driving motor rotation path to prevent seal blowout.
EAA-41Port Connection Code & Design Sequence NumberAligns inlet/outlet orientations to original Japanese plumbing configurations.

Precision Tooling: Engineered for Low Noise & High Volumetric Efficiency

Running a double vane pump continuously under heavy workshop cycles demands extreme micro-dimensional accuracy. Non-specialized traders supply castings with unground landing zones, leading to early pressure bypass, high operating heat, and rapid volumetric decay. We eliminate these failure points directly on our factory floor:

  • Circular Arc Vane Geometry: Our PV2H23 series incorporates dual-vane pin tracking mechanisms. Vanes are hydrostatically balanced under peak line pressures, significantly lowering friction against the stator ring and dropping noise below 68 dB(A) for comfortable workshop operations.

  • Sub-Micron CNC Profiling: Stator cam ring tracking contours and rotor side sealing plates are ground to sub-micron tolerances on specialized vertical CNC profile grinders, guaranteeing zero internal boundary leakage.

  • 100% Full-Load Bench Test Validation: Every single PV2H23 double pump is dynamic tested up to its peak pressure limits on our hydraulic calibration bench. We verify both chambers simultaneously before crating.

Pro Maintenance Insight: Escape the Hostile "Sandpaper Effect"

When should you execute an urgent double pump overhaul? If your central system starts presenting sudden cycle slowdowns under load, localized oil reservoir temperature spikes, or produces a harsh, high-frequency metallic screaming from the pump housing, internal vane tracking degradation has begun.

CRITICAL FLUID SYSTEM REPLACEMENT REGULATION: High-pressure intra-vane pumps depend on precision micro-clearances between the stator, rotor, and side plates. When a previous pump suffers dynamic mechanical failure, countless hard microscopic metal filings instantly shear off and are swept throughout the reservoir tank and manifold loops.

If your technical crew simply bolts a fresh new replacement pump onto the system without deep cleaning the circuit, these residual hard particles will act as an aggressive grit abrasive—creating a devastating "sandpaper effect". They will instantly score the freshly ground stator profile rings, destroying your new double pump within a few operating hours.

Mandatory Procedure: Meticulously drain and flush the reservoir oil tank, thoroughly scrub the suction intake strainers, and install a brand-new 10-micron absolute premium return fluid filter concurrently with the new pump unit installation.

Frequently Asked Questions: Yuken PV2H23 Series Double Pumps

1. Is this PV2H23-26-94-F-REAA-41 double pump 100% drop-in interchangeable with original Japanese Yuken pumps? +
Yes, 100%. Our replacement high-pressure double vane pump is manufactured strictly to original Japanese Yuken PV2H23 dimensional standards. Mounting flange pilot diameters, keyed drive shaft dimensions, suction and dual discharge port locations, and bolt-hole configurations match the original footprint identically, allowing direct bolt-on installation with zero pipeline alterations.
2. What displacement and operating pressure capabilities do the dual sections of the PV2H23-26-94 pump deliver? +
The PV2H23-26-94 model combines a heavy-duty PV2H2 front section (26.0 cm³/rev) with a high-flow PV2H3 rear section (94.0 cm³/rev). Combined, they yield a total displacement of approx. 120.0 cm³/rev. Both chambers operate reliably under high working pressures up to 21.0 MPa (210 bar / 3045 PSI), optimizing high-low circuit energy performance.
3. Can we rebuild individual chambers using modular replacement cartridge kits? +
Yes, absolutely. Both chambers in the PV2H23 frame feature modular, pre-assembled cartridge kit designs (rotor, vanes, cam ring, and side plates). If only one chamber undergoes internal wear, you can purchase individual replacement PV2H2 or PV2H3 cartridge kits from us to rebuild the pump housing on-site in under 15 minutes, cutting MRO expenses significantly.

Request Direct Factory Wholesale Pricing Now

Looking to bypass third-party trading agent markups and heavy brand taxes? Secure micro-tolerance, low-noise PV2H series double vane pumps shipped directly from our precision manufacturing line today.

Get An Instant Factory Price Quote
Related Products6
Product Tag
Get the latest price? We'll respond as soon as possible(within 12 hours)