4535V, 3525V and 4525V: Select Both Outlets and the Shared Drive
YHDE offers Vickers-type industrial V-series double vane pump replacement assessments for 4535V, 3525V and 4525V applications. Two fixed-displacement pumping elements share an inlet and input shaft while supplying separate outlet flows. Start with the complete installed model and the duties of both circuits.
Two outlets still share one drive. Confirm the combined input torque, selected shaft, fluid and timed loading cycle before approving a complete pump. A frame number, separate pressure rating or visual resemblance does not establish interchangeability.
Match the Front and Rear Frame Combination
The original-family values below come from the Vickers by Danfoss industrial V-series reference [1]. They identify the application; confirm the actual YHDE supply drawing, approved duty and inspection scope with the quotation.
| Model | Front / shaft end (P1 in this guide) | Rear / cover end (P2 in this guide) | Reference displacement range, cm³/rev |
|---|---|---|---|
| 3525V | 35V | 25V | P1: 81–121; P2: 33–67 |
| 4525V | 45V | 25V | P1: 138–193; P2: 33–67 |
| 4535V | 45V | 35V | P1: 138–193; P2: 81–121 |
These frame names are not complete order numbers. Flow codes, pilot/mounting version, shaft, hydraulic connection threads, outlet positions, design, seals and rotation still require matching. V and VQ are different specification families; do not transfer VQ pressure or speed ratings to this listing.
Convert Each Rated-Flow Code to Its Geometric Displacement
Flow codes refer to rated USgpm at 1200 r/min and 6.9 bar, not displacement in cm³/rev. The following mapping uses the double-pump model-code table. Keep the section order and original markings.
| Rated-flow code | Geometric displacement, cm³/rev |
|---|---|
| 10 | 33 — model-table option; pressure and supply confirmation required |
| 12 | 40 |
| 14 | 45 |
| 17 | 55 |
| 21 | 67 |
| Rated-flow code | Geometric displacement, cm³/rev |
|---|---|
| 25 | 81 |
| 30 | 97 |
| 35 | 112 |
| 38 | 121 |
| Rated-flow code | Geometric displacement, cm³/rev |
|---|---|
| 42 | 138 |
| 45 | 147 — model-table option; double-pump pressure and supply confirmation required |
| 50 | 162 |
| 60 | 193 |
The selected catalogue pressure table explicitly lists 25V double-pump codes 12/14/17/21 and 45V double-pump codes 42/50/60. Code 10 in the 25V model table and code 45 in the 45V model table need configuration-specific confirmation. Codes such as 47, 57, 66 or 75 are not established by this selected reference; send the full nameplate for a separate supply review.
Size Flow and Power at the Actual Common Speed
For each element, ideal flow is Q = Vg × n ÷ 1000 in L/min with cm³/rev and r/min. A 3525V 38/21 pair at 1500 r/min gives ideal flows of 181.5 and 100.5 L/min. Loaded delivery is lower and depends on the pressure and losses of each section. Ask for separate flow results at the required working points.
Hydraulic output power is (Δp₁Q₁ + Δp₂Q₂) ÷ 600 in kW using actual delivered flows. Actual input power includes losses. Review continuous loading, unloading and starting duty together with the motor and coupling.
Pressure, Fluid and Speed Must Be Reviewed Together
| Applicable elements / codes | Anti-wear oil or phosphate ester* | Water-in-oil emulsion | Water glycol |
|---|---|---|---|
| Front 35V: 25/30/35/38; rear 35V on 4535V: 25/30/35/38 | 172 bar | 69 bar | 159 bar |
| Front 45V: 42/50/60 | 172 bar | 69 bar | 159 bar |
| Rear 25V: 12/14/17/21 | 172 bar | 69 bar | 159 bar |
*Fluid-compatible seals and construction are required. The cited catalogue permits a transient pressure up to 10% above the continuous rating for no more than 0.5 seconds. This is not a sustained intermittent setting; the shaft, inlet and all other operating limits still apply. Obtain the offered replacement’s approved envelope before using this allowance.
| Condition | Catalogue reference |
|---|---|
| Minimum speed, all listed fluid combinations | 600 r/min |
| Standard models using anti-wear fluid | Maximum 1800 r/min |
| Standard models using synthetic or water-in-oil emulsion | Maximum 1200 r/min; additional fluid guidance required |
| Water glycol | Maximum 1500 r/min; additional fluid guidance required |
Review viscosity, temperature, inlet pressure, suction restrictions and seal compatibility. The 600–1800 r/min range cannot be presented as universal for every fluid, starting condition or special construction.
Check Combined Input Torque Before Simultaneous Loading
The catalogue requires the sum of both element input torques to remain within the applicable shaft limit. Its 3525V38A17 example at 172 bar front and 138 bar rear requires over 450 N·m and excludes shaft code 1 [1]. This demonstrates why individually acceptable element pressures do not approve a complete double-pump duty.
The 35-frame reference shaft limits are 400 N·m for code 1, 580 N·m for code 11 and 600 N·m for code 86. Confirm availability for the exact pilot/design and the supplied shaft rating. The selected catalogue’s 45-frame code-1 row contains inconsistent N·m and lb-in values, so request written clarification and a supplied-pump rating before approving 4525V or 4535V loading.
For preliminary understanding, ideal torque is (Δp₁V₁ + Δp₂V₂) ÷ (20π) in N·m. Actual input includes losses; use the manufacturer’s input-torque data and full loading cycle for final selection.
Read the Complete Code and the Correct Porting Diagram
Example for field identification: 3525V-38A21-1CC-22R. This identifies a reference arrangement for an inquiry; it does not approve a combined operating duty on shaft code 1.
| Field | Reference meaning | What to confirm |
|---|---|---|
| 3525V / 4525V / 4535V | Front/rear frame combination | Actual complete model and any special suffix |
| Flow codes before and after A | Front and rear rated-flow codes | Geometric displacement, loaded flow and section order |
| A | SAE four-bolt hydraulic flange connection | Port dimensions and adapters; A is not a mounting-pilot code |
| M after A, when present | Metric hydraulic connection-thread modifier | Distinguish from a pilot modifier M after the series designation |
| Pilot version: omitted / S / M | Standard / SAE per ISO 3019/1 / metric per ISO 3019/2 | Full installation drawing; do not assume every standard version is SAE |
| Shaft code, e.g. 1 / 11 / 86 | Keyed or splined option in applicable shaft data | Dimensions, pilot/design availability, coupling and combined torque rating |
| Two-letter code, e.g. CC | No.1 and No.2 outlet positions, viewed from cover end | Use the correct model-specific porting table below |
| 22 | Design number in the reference model | Keep actual design and parts version |
| R / L | Clockwise / counterclockwise viewed from shaft end | Match the marked pump and drive rotation; do not assume reversible operation |
| F3 prefix / other suffixes | Seal option or special configuration | Actual fluid, temperature, seal specification and modification drawing |
| Code | No.1 outlet, both groups | No.2: 3525V / 4525V | No.2: 4535V |
|---|---|---|---|
| AA | Opposite inlet | 135° counterclockwise from inlet | Opposite inlet |
| AB | Opposite inlet | 45° counterclockwise from inlet | 90° counterclockwise from inlet |
| AC | Opposite inlet | 45° clockwise from inlet | Inline with inlet |
| AD | Opposite inlet | 135° clockwise from inlet | 90° clockwise from inlet |
| CC | Inline with inlet | 45° clockwise from inlet | Inline with inlet |
Check the complete diagram for all other two-letter combinations. Shaft rotation uses the opposite viewing reference: the shaft end. Send photographs or a drawing showing inlet, both outlets, mounting pilot, bolt pattern, shaft and available envelope. Confirm flange kits, fasteners and adapters as separate supply items.
Choose Front Cartridge, Rear Cartridge or Complete-Pump Assessment
The rotor, vanes, intra-vane elements, cam ring and mating plates form the pumping cartridge. Balanced pressure areas reduce internally induced radial loading. Mating-surface condition, clearances, cleanliness and lubrication affect delivery and heat; performance and noise must be checked under stated conditions.
| Request | Evidence and inspection |
|---|---|
| Complete pump | Actual full model, both duties, shared drive, all interfaces and supply drawing |
| Front cartridge | 35V element on 3525V; 45V element on 4525V/4535V. Confirm markings, rotation, design and mating parts |
| Rear cartridge | 25V element on 3525V/4525V; 35V element on 4535V. Confirm markings, rotation, design and mating parts |
| Repeated noise, heat or low flow | Separate outlet pressure/flow, common speed, inlet conditions, oil/debris findings, coupling, shaft, bearings and housing |
Isolate the drive and hydraulic energy, release stored pressure and secure the machine before service.
Inspect both elements and the supporting housings, shaft, bearings, plates and seals before deciding that a cartridge alone is sufficient.
Remove contamination and its cause. Select filtration by the system cleanliness target, flow, viscosity and cold-start pressure drop.
Use the applicable assembly, priming and air-removal procedure, confirm rotation and avoid dry running.
Record flow, pressure, speed, temperature and leakage for each outlet and for the approved combined duty.
Browse V / VQ pump families · Browse V / VQ cartridge categories. Category navigation does not establish V/VQ interchangeability; request a specific front/rear parts match and itemized kit contents.
Prepare a Pump or Section-Specific Repair Inquiry
Choose the requested frame and copy the actual full model. The table above shows the appropriate front/rear groups. Keep any non-standard code in your request for identification. Price, availability, specification and dispatch date are confirmed in the quotation.
Review the model and both outlet duties, enter your email and submit when ready.
Prepare nameplate, mounting, shaft and all port photographs or drawings. For repair add cartridge markings and symptoms. The current form has no attachment input: describe the files available and ask how to send them. Include fluid, viscosity, temperature, inlet conditions, quantity, destination and required date. Request the proposed drawing, supply ratings, combined-drive approval, inspection scope, itemized price and delivery estimate.
The selected fields prepare an engineering inquiry; they do not validate compatibility or automatically create an approved order code. If prefill is unavailable, include the same details directly in the inquiry message.
V-Series Double Pump Selection and Repair Questions
How do 3525V, 4525V and 4535V differ?
The first frame identifies the shaft-end pumping element and the second identifies the cover-end element. The combinations are 35V plus 25V, 45V plus 25V, and 45V plus 35V respectively. Match both displacement codes and the complete mounting, shaft, connection and rotation fields.
Are the flow codes the displacement in cm³/rev?
No. They identify rated USgpm at 1200 r/min and 6.9 bar in the cited double-pump model table. Use its separate geometric-displacement mapping for sizing. For example, front 35V code 38 is 121 cm³/rev and rear 25V code 21 is 67 cm³/rev.
What pressure and speed reference should I use?
For the listed industrial double-pump codes, the cited catalogue gives 172 bar continuous with anti-wear oil, subject to the fluid and shaft conditions. Standard anti-wear-fluid speed is 600 to 1800 r/min. Other fluids have different limits. Confirm the actual supplied construction; VQ ratings and speed limits do not automatically apply to V pumps.
Can both sections run at their maximum pressure together?
Only after the combined input torque and complete duty have been checked. The catalogue example of a 3525V38A17 at 172 bar front and 138 bar rear requires over 450 N·m and excludes shaft code 1. Separate section pressure limits do not approve simultaneous loading.
Does CC mean the same port arrangement on all three frames?
No. Viewed from the cover end, CC gives No.1 outlet inline with the inlet. For 3525V and 4525V, No.2 outlet is 45 degrees clockwise from the inlet; for 4535V, No.2 outlet is inline with the inlet. Match the applicable diagram and actual drawing.
Can I replace only one cartridge?
Identify the front or rear element, actual cartridge markings, rotation, design and seal requirements. Inspect both elements and the shaft, bearings, housings and mating plates. A cartridge alone may not correct supporting-component damage, inlet faults or contamination. Confirm the kit contents and assembly procedure.
What information is needed for a quotation?
Provide the complete installed model, requested frame and both flow codes, separate working and peak pressures with duration, required loaded flows, common speed and loading sequence, motor and coupling, fluid and inlet conditions, mounting and port drawings, quantity and destination. For repair, add symptoms and part markings.
Technical Reference
[1] Vickers by Danfoss: V Series — Low Noise Vane Pumps, BC443076030451en-000101. See printed pages 6, 8, 23–25, 31–34 and 37 for operating conditions, model fields, installation, shafts, torque and service information.
Original-family data identify the application. Confirm the actual supplied replacement’s drawing, fluid compatibility, ratings and approved duty. Vickers and Eaton/Danfoss names identify reference applications.