• PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE
  • PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE
  • PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE
  • PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE
  • PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE
  • PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE

PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE

Brand: Yihe

Product origin: China

Delivery time: 5-30days

Supply capacity: 300pcs/day

High-performance PV2R2-41 hydraulic vane pump, 100% interchangeable with Yuken. Factory-direct from YHDE with 9+ years expertise. Features ultra-low noise, 21 MPa max pressure, and 41 ml/r displacement. Fast global shipping. Request a technical quote!

Download:

PV2R2-41 Hydraulic Vane Pump | 100% Yuken Compatible | YHDE

PV2R2-41-F-RAA-41 Vane Pump: Match the Complete Configuration

YHDE offers a Yuken-type PV2R2-41-F-RAA-41 fixed-displacement single vane pump replacement. Match the required loaded flow and fluid-dependent operating conditions with the complete installed model, flange, shaft and port arrangement before confirming a replacement.

Nominal code 41 identifies a 41.3 cm³/rev original reference. The full model also specifies mounting, rotation, two port positions and design. Request the offered YHDE drawing and approved duty, rather than selecting by displacement alone.

View the original PV2R2 installation drawing · Read Yuken PV2R operating instructions. These identify the original family; confirm the supplied replacement separately.

PV2R2-41 Specifications and Fluid Conditions

The following original-family values come from Yuken catalogue [1], JH-0161 [2] and the PV2R2 design-41 drawing [3]. They support identification and application review; they are not inspection results for a supplied YHDE pump.

PV2R2-41 original reference
ParameterReference valueSelection condition
ConstructionSingle fixed-displacement vane pumpConfirm actual manufacturer and full design.
Geometric displacement41.3 cm³/revNominal code 41 is not an exact 41.0 cm³/rev flow calculation.
Anti-wear petroleum oil21 MPa / 210 bar maximum working pressureCheck the complete supplied pressure, speed, fluid and inlet envelope.
Petroleum-oil speed600–1800 r/minStarting viscosity limits apply at low speed.
Water-containing / phosphate-ester speed1200 r/min maximum in this referenceApply the appropriate fluid pressure limits and seal construction.
Mounting / rotationF: flange; R: clockwise from shaft endMatch actual shaft, mounting and drive direction.
Port positionsOutlet A upward / inlet A upwardPositions are viewed from the shaft end.
PV2R2-41 maximum working pressure by fluid [1,2]
Fluid groupReference maximumConstruction / duty check
Anti-wear petroleum oil21 MPa / 210 barUse approved oil and the permitted operating conditions.
Ordinary petroleum oil14 MPa / 140 barDo not apply the anti-wear-oil rating automatically.
Approved anti-wear water glycol16 MPa / 160 barConfirm the approved fluid and maximum speed.
Non-anti-wear water glycol / water-in-oil emulsion7 MPa / 70 barUse the specified fluid limits.
Phosphate ester14 MPa / 140 barRequires compatible special seals; original model has a leading F- prefix.

21 MPa is a conditional maximum working-pressure reference. It is not a generic surge allowance or a rating for every oil. Provide working and peak pressures with duration, actual speed and the full operating cycle.

Starting and Inlet Conditions

JH-0161 lists PV2R2 low-speed starting viscosity limits of 100 mm²/s at 600 r/min and 200 mm²/s at 950 r/min. Check oil temperature and viscosity together before starting.

The same original reference specifies pump-inlet pressure of −20 to +30 kPa gauge for petroleum oil and −16 to +30 kPa gauge for the listed water-containing/phosphate-ester fluids. Measure at the pump inlet and distinguish gauge from absolute pressure. Confirm the actual supplied limits.

Decode PV2R2 – 41 – F – R – A – A – 41

Model fields from the original reference [1–3]
FieldMeaningMatch before ordering
PV2R2Frame-size-2 single vane pump familyDo not substitute a double pump or another frame by similar name.
First 41Nominal displacement code; 41.3 cm³/revCompare required loaded flow at operating pressure and speed.
F after displacementFlange mountingL in this field is foot mounting; compare the actual drawing.
RClockwise viewed from the shaft endConfirm marked rotation and motor direction.
First ADischarge port upward, shaft-end viewMatch the outlet location.
Second ASuction port upward, shaft-end viewMatch the inlet location.
Final 41Design numberPreserve the actual design and any extra suffixes when identifying parts.

A leading F- before PV2R2 identifies a special fluororubber-seal construction in the original reference. It is a different field from the mounting F after the displacement. Do not infer phosphate-ester compatibility from the mounting F alone.

Confirm Shaft, Mounting and Hydraulic Connections

Original PV2R2 flange-mount drawing checkpoints [1,3]
InterfaceReference checkpointWhat remains to verify
Drive shaftNominal Ø25.4 mm keyed shaftTolerance, key, shaft length, coupling engagement and allowable load.
Mounting pilotNominal Ø101.6 mmTolerance and mating register.
Mounting holes146 mm two-hole spacingHole size, fasteners, strength and tightening requirements.
Hydraulic portsSuction bore Ø34 mm; discharge bore Ø21 mmFlange pattern, threads, depth, sealing and pipe clearance.
Port positions / envelopeF-RAA layout; original drawing includes full dimensionsConfirm offered drawing and actual installation space.

Bore diameter is not a pipe-thread specification. Compare the complete hydraulic port-flange connection, including fastener thread and depth. Keep the installed design/suffix and request a drawing match before approving interchangeability.

Browse PV2R pump families. Other displacements, foot mounts, rotations, designs and PV2R double pumps require their own comparison.

Check Loaded Flow, Input Power and Noise Conditions

Theoretical flow is Q = Vg × n ÷ 1000, using cm³/rev and r/min. For the 41.3 cm³/rev reference at 1500 r/min, theoretical flow is 61.95 L/min. Actual loaded delivery depends on pressure, oil viscosity, temperature and internal losses.

Hydraulic output power is P = Δp × Q ÷ 60 kW with MPa and actual L/min. Using theoretical flow at 21 MPa gives an illustrative 21.68 kW hydraulic value; actual input power includes losses. Select the motor and coupling from the approved duty and input-power data.

The original catalogue provides typical noise curves with defined conditions, including 20 mm²/s viscosity, measurement 1 m behind the pump and 40 dB(A) background noise. Speed, pressure, piping and mounting affect the result. Request a defined supply test point rather than an unconditional sound-level guarantee.

For inspection, specify pressure, speed, fluid, temperature and duration, then request measured flow, input power and leakage, plus noise results where required. Original curves do not certify the offered replacement.

Match the Cartridge and Inspect the Complete Pump

The rotor, vanes, cam ring and mating distribution/side plates form the pumping element. As the rotor turns, changing chamber volume moves fluid from the inlet to the outlet. The matched surfaces, clearances and lubrication affect delivered flow, heat and wear.

Low output, noise or heat can also come from inlet restriction or air entry, unsuitable oil, coupling/alignment problems or circuit leakage. Verify the actual construction before attributing it to a pin or dual-vane mechanism from another family.

Select the service scope from the findings
RequestEvidence and inspection scope
Complete PV2R2-41 replacementFull model/maker, pressure and flow duty, speed/fluid, shaft, flange, port drawing and installation space.
Matched PV2R2-41 cartridgeActual kit and pump markings, rotation, design, locating features, plates and itemized contents.
Fault / repair assessmentLoaded-flow and pressure readings, temperature, inlet condition, oil/debris findings, coupling and circuit checks.
Repeat failure / scoringInspect cartridge, housing, shaft, bearings and seals; find and remove the contamination or operating cause.

Yuken’s cited parts table identifies CPV2R2-41-R-41 as the original-reference cartridge for the corresponding clockwise design-41 pump [1]. Confirm the actual offered kit and mating construction; this reference does not certify aftermarket interchangeability. Shaft oil seals and bearings are listed separately from the cartridge, so request an itemized repair package.

  1. Isolate the drive and hydraulic energy, release stored pressure and secure the machine before service.

  2. Inspect the cartridge and supporting shaft, bearings, housings and seals.

  3. Remove contamination and its cause. Select filtration by cleanliness target, flow, viscosity and cold-start pressure drop.

  4. Follow the applicable assembly, filling/priming and air-removal procedure. Confirm rotation and start unloaded as specified.

  5. Record pressure, loaded flow, speed, oil temperature and leakage at the approved duty.

Identify a PV2R cartridge or parts request. Confirm repair feasibility and included parts from inspection; repair time and pipe access depend on the machine arrangement.

PV2R2 Drawings, Instructions and Technical References

Use these original-family documents to identify the application. Request the specific YHDE supply drawing, ratings and inspection documents with your quotation.

Product Overview Video

Prepare a Model-Specific Inquiry

Enter the installed model and requirements, then choose your request. Ask for the proposed configuration, supplied drawing, approved duty, inspection scope, itemized price and dispatch estimate.

Review the actual model and duty, enter your email and submit when ready.

Prepare nameplate, mounting, shaft and port photographs or drawings. The current form has no attachment input: describe the files available and ask how to send them. For repair, include measured readings and cartridge markings. If prefill is unavailable, add these details directly to your message.

PV2R2-41 Selection and Repair Questions

What is the displacement of PV2R2-41?

Nominal code 41 maps to 41.3 cm³/rev in the cited Yuken reference. At 1500 r/min that gives 61.95 L/min theoretically. Loaded delivery depends on pressure, fluid conditions and losses.

Is 21 MPa a universal peak or continuous rating?

The cited 21 MPa value is maximum working pressure for PV2R2-41 with anti-wear petroleum oil under the specified conditions. Other fluids have different limits. Confirm the complete supplied duty rather than treating it as a universal surge allowance.

Is the minimum reference speed 750 r/min?

For PV2R2, the cited original reference gives 600 r/min, with starting-viscosity restrictions. Petroleum-oil maximum speed is 1800 r/min, while the listed water-containing and phosphate-ester fluids use a 1200 r/min maximum. Confirm the actual supplied envelope.

What do F-RAA-41 and a leading F- mean?

The F after displacement is flange mounting, R is clockwise from the shaft end, the first A is outlet upward, the second A is inlet upward, and final 41 is design number. A leading F- before the series identifies a separate special-seal construction in the original reference.

Where can I find a PV2R2 PDF or installation drawing?

Use the original Yuken PV2R2 design-41 installation drawing, JH-0161 instructions and single-pump catalogue linked in this guide. Confirm their applicability to the actual pump and request the offered replacement drawing and ratings.

Can a cartridge alone repair every fault?

No. Match the actual cartridge, direction, design and mating parts, then inspect the shaft, bearings, housing, seals, inlet and circuit. The original parts table lists shaft oil seals and bearings separately. Confirm the complete repair scope and included parts.

What should I send for a replacement quotation?

Provide the actual full model and maker, working/peak pressure with duration, loaded flow and speed, drive cycle, fluid and inlet conditions, shaft/mounting/port drawings, quantity, destination and required date. For repair, add symptoms, readings and cartridge markings.

Related Products6
Product Tag
Get the latest price? We'll respond as soon as possible(within 12 hours)