PV2R13 Double Vane Pump | 100% Yuken Compatible | YHDE Hydraulics
Brand: YiHe
Product origin: China
Delivery time: 10-30days
Supply capacity: 300pcs/day
High-performance PV2R13 double hydraulic vane pump, 100% interchangeable with Yuken PV2R series. Features ultra-low noise and high pressure. Factory-direct from YHDE with 9+ years expertise. Fast shipping & 100% tested.
Eliminate Dual-Circuit Press Stalls: Precision Yuken PV2R13-31-116 Drop-In Replacement
When an asymmetrical double hydraulic vane pump suffers internal cross-leakage, loses holding pressure under high-tonnage clamp loads, or generates loud cavitation whine in your plastic injection molding machines, die-casting extractors, rubber forming presses, or centralized hydraulic power units, waiting 12 to 16 weeks for imported Japanese OEM replacements paralyzes production lines.
Our premium Yuken Compatible PV2R13-31-116-F-REAA-42 High-Pressure Low-Noise Double Hydraulic Vane Pump serves as a direct 100% mechanical drop-in replacement. Manufactured in our ISO-compliant production facility with micro-clearance coordinate grinding and hydraulic tooling expertise, this unit combines high-volume Frame 3 flow (115.6 cm³/rev) with precise Frame 1 delivery (31.0 cm³/rev) under continuous 210 bar reliability—slashing your plant MRO procurement expenses by up to 70%.
100% Mechanical Interchangeability: Pilot mounting flange, cylindrical straight keyed drive shaft, common suction intake, and independent dual discharge ports align with Yuken specifications identically with zero system re-piping.
Direct Factory Inventory: Standard displacement pairs are pre-assembled from precision component reserves, full-pressure dynamically bench tested, and dispatched worldwide within 24-48 hours.
Technical Specifications & Operational Parameters
Cross-verify your equipment's operating pressure ratings, displacement requirements, and speed ranges using the technical data below:
| Parameter Attribute | Engineering Specification Value | Application System Advantage |
|---|---|---|
| Displacement - Frame 1 (P1) | 31.0 cm³/rev (ml/r Nominal Code 31) | Provides dedicated, stable volumetric delivery for high-pressure clamping, core pulls, or pilot circuits. |
| Displacement - Frame 3 (P2) | 115.6 cm³/rev (ml/r Nominal Code 116) | Supplies massive volumetric flow for rapid mold advance, high-speed ram travel, and primary press cycles. |
| Max Continuous Pressure | Up to 210 bar (21.0 MPa / 3000 PSI Continuous) / 230 bar Peak Intermittent | High-density close-grained cast housing resists internal deflection under sharp dual-circuit pressure spikes. |
| Operating Speed Band | 600 - 1800 r/min (Standard Industrial Operating Range) | Directly compatible with standard 4-pole and 6-pole AC electric motors and variable-speed prime movers. |
| Operational Noise Level | Strictly Under 68 dB(A) at Full Operating Load | Acoustically tuned cam track profiling eliminates pressure pulsation chatter and lowers workshop decibels. |
| Volumetric Efficiency | ≥ 93% Across Standard Operating Temperatures | Sub-micron precision sealing surfaces minimize internal slip and reduce oil reservoir heating. |
Model Ordering Nomenclature Decoded: PV2R13-31-116-F-REAA-42
| Code Segment | Technical Specifications Meaning | System Installation Alignment Reference |
|---|---|---|
| PV2R13 | Low-Noise High-Pressure Double Vane Pump (Frame 1 + Frame 3 Combination) | Asymmetrical dual-core housing powered by a single heavy-duty drive shaft. |
| 31 | Frame 1 Cartridge (P1) Nominal Displacement: 31.0 cm³/rev (ml/r) | Determines auxiliary or clamping flow rate relative to drive motor RPM. |
| 116 | Frame 3 Cartridge (P2) Nominal Displacement: 115.6 cm³/rev (ml/r) | Determines primary delivery flow rate relative to drive motor RPM. |
| F | Mounting Scheme: 2-Bolt Pilot Flange Mounting | Standard bell-housing flange ensures accurate concentric alignment with the prime mover. |
| R | Clockwise Rotation (Right-Hand viewed from shaft extension) | Must correspond to electric motor rotation to protect internal rotating groups. |
| EAA | Port Position Configuration: Suction & Dual Discharge Orientations | Matches original factory piping schematics for seamless drop-in hookup. |
| 42 | Design Number Series (Series 42 Standardization) | Ensures full internal cartridge and dimensional interchangeability across series 42 units. |
Precision Tooling: Engineered for Asymmetrical Dual-Circuit Stability Under 210 Bar
Coupling a compact Frame 1 cartridge (31.0 cm³/rev) with a heavy Frame 3 cartridge (115.6 cm³/rev) on a single drive shaft induces severe torsional loading differentials and asymmetric hydraulic forces. Standard commercial double pumps frequently suffer shaft deflection, premature bearing failure, and port cross-talk under these uneven duty cycles. We resolve these issues through strict manufacturing controls:
Reinforced High-Torque Drive Shaft: Forged from high-grade alloy steel and heat-treated for superior fatigue resistance, ensuring reliable torque transfer across both Frame 1 and Frame 3 rotating groups without angular twist.
Computer-Generated Cam Curvature: Stator cam contours are ground on CNC coordinate contour grinders, ensuring gradual acceleration and deceleration of the vanes to suppress hydraulic pulsation chatter and maintain operating sound below 68 dB(A).
Damping-Enhanced Heavy Iron Body: Cast from high-density gray iron with superior vibration dampening properties, preventing structural deflection during severe multi-circuit pressure transients.
100% Full-Pressure Bench Testing: Every PV2R13 double pump undergoes independent multi-point dynamic bench testing to verify dual-circuit flow rates, pressure retention, and zero external leakage before shipment.
Pro Maintenance Insight: Prevent the Destructive "Sandpaper Effect"
When should you replace your double pump? If your machinery experiences sluggish clamp lockup, loss of cylinder traverse speed, uneven circuit pressures, or severe high-frequency whining during pressure holding, internal cam track and vane wear has occurred.
Installing a fresh double pump without thoroughly purging both fluid lines forces these abrasive particulates into the new unit—causing the destructive "sandpaper effect". These particles will rapidly score both freshly ground cam rings, destroying the replacement pump within hours of startup.
Mandatory Procedure: Drain and chemically flush the oil reservoir, clean the common suction strainer, inspect all return lines, and install a brand-new 10-micron absolute return line filter element concurrently with pump commissioning.
Frequently Asked Questions: Yuken PV2R Series Double Pumps
1. Is this PV2R13-31-116-F-REAA-42 double pump 100% interchangeable with original Yuken pumps? +
2. What displacement and operating pressure specifications does the 31-116 cartridge combination deliver? +
3. Can the internal Frame 1 and Frame 3 cartridge kits be serviced independently? +
Request Direct Factory Wholesale Pricing Now
Looking to bypass trading intermediaries and eliminate prolonged overseas lead times? Source high-efficiency Yuken PV2R13 series low-noise double vane pumps directly from our precision production facility today.
Get An Instant Factory Price Quote