3525V-38A21-1CC-22R Double Vane Pump | Vickers Replacement | YHDE
Brand: YIHE
Product origin: CHINA
Delivery time: 10-30days
Supply capacity: 300PCS/day
High-performance 3525V-38A21 double vane pump, 100% interchangeable with Vickers (Eaton). Features dual flow sections (38 GPM & 21 GPM). Factory-direct from YHDE with 9+ years of manufacturing expertise. Rugged, quiet, and 100% tested. Get a fast quote!
Bypass 16-Week Lead Times for a Vickers 3525V Double Pump. Restore Production Power in 48 Hours!
When a heavy-duty hydraulic double pump fails in your industrial scrap compactor, plastic injection molding machinery, or marine deck winch, waiting 12 to 20 weeks for genuine Eaton Vickers distributors severely bleeds your facility's daily profitability.
Our premium Vickers-type 3525V-38A21-1CC-22R Double Hydraulic Vane Pump serves as a seamless, 100% "drop-in" mechanical replacement. Manufactured in our specialized ISO-compliant direct factory with 9+ years of micro-tolerance precision engineering, this dual-flow pump restores original system pressure limits and volumetric speeds at up to 70% budget savings.
100% Mechanical Drop-In Fit: Dimensions, mounting flanges, straight keyed drive shaft, and port alignments are completely identical to original specifications.
24-48 Hour Shipping: Built from factory component reserves, full-load tested, and dispatched to reduce your factory downtime instantly.
Technical Specifications & Operating Thresholds
Cross-verify your equipment's operating pressure curves and circuit flow rates with our engineering master specs below:
| Parameter Attribute | Shaft-End Section (35V Frame) | Cover-End Section (25V Frame) | Operating Limit Benefit |
|---|---|---|---|
| Nominal Displacement Flow | 38 USgpm (at 1200 rpm, 6.9 bar) | 21 USgpm (at 1200 rpm, 6.9 bar) | Combines high-volume action and medium-volume pilot control. |
| Max Operating Pressure | 172 bar (17.2 MPa / 2500 PSI) | 172 bar (17.2 MPa / 2500 PSI) | Withstands continuous high clamping loads without housing fatigue. |
| Rated Rotation Speed | 600 - 1800 r/min (RPM) | 600 - 1800 r/min (RPM) | Pairs perfectly with standard industrial electric AC/DC motors. |
Nomenclature Coding Decoded: 3525V-38A21-1CC-22R
| Code Segment | Technical Specifications Meaning | System Installation Match |
|---|---|---|
| 3525V | Double Intra-Vane Type High-Pressure Pump Series | Standardized physical footprint for 35V (front) and 25V (rear) frames. |
| 38 / 21 | Nominal Displacements (38 USgpm / 21 USgpm) | Calculates direct volume flows and mechanical velocity targets. |
| 1 | Shaft Configuration: Straight Keyed Shaft | Directly matches original straight keyways with standard coupling pulleys. |
| CC | Outlet Port Position Placement Option | Standard right-angle port alignment with inlet paths. |
| 22R | Design Sequence Code + Clockwise (CW) Rotation | Secures exact drive direction alignment to prevent suction seal blowouts. |
Precision Manufacturing: Why Heavy Industry Buyers Partner with YHDE
Dual high-pressure pumps running continuously in molding and press workshops endure relentless fluid friction and volumetric loading stresses. Poorly ground generic trading pumps bypass oil internally, leading to immense system heat, early pressure dropoffs, and immediate seal degradation. We defeat these structural vulnerabilities directly at our factory:
Intra-Vane Pressure Compensation Design: Our 3525V cartridges utilize the intra-vane technique. Oil pressure applies balancing forces under the vane pins, minimizing rotor ring wear patterns and holding volumetric efficiency at a steady 92%-95% under pressure loads.
Honed Micron Tolerances: Stator cam ring tracking contours and rotor side sealing faces are ground to sub-micron clearances on specialized vertical CNC grinders, locking noise levels below 68 dB.
100% Full-Load Bench Calibration: Every single double pump is dynamic tested on our hydraulic calibration bench up to its maximum rated 172 bar limit. We guarantee zero start-up bypass issues or pressure drops out of the box.
Pro Maintenance Insight: Escape the Destructive "Sandpaper Effect"
**When should you execute an urgent pump overhaul?** If your double system displays localized oil overheating, a noticeable drop in stroke cycle speed, or produces a harsh metallic screaming from the housing, internal vane tracking degradation is actively happening.
If your technical crew simply bolts a fresh new replacement pump onto the system without deep cleaning the circuit, these residual hard particles will act as an aggressive grit abrasive—creating a devastating "sandpaper effect". They will instantly score the freshly ground stator profile rings, destroying your new double pump within a few operating hours.
Mandatory Procedure: Meticulously drain and flush the reservoir tank, scrub intake suction strainers, and install a brand-new 10-micron absolute premium return fluid filter concurrently with the new pump unit installation.
Frequently Asked Questions: 3525V Series Replacement Pumps
1. Is this 3525V-38A21-1CC-22R double pump fully interchangeable with the original Eaton Vickers brand? +
2. What are the flow rate capacities of the dual sections on this double pump? +
3. Do you maintain components for custom displacement combinations on the 3525V frame? +
Request Direct Factory Wholesale Pricing Now
Looking to bypass third-party trading agent markups and heavy brand taxes? Get high-efficiency double vane pumps shipped straight from our Foshan precision manufacturing facility today.
Get An Instant Factory Price Quote