KSO-G02 / KSO-G03: Match the Valve, Spool and Coil
YHDE supplies Daikin-type KSO directional valves for replacement enquiries. Identify the complete installed configuration before selecting a valve or service part. Similar appearance and nominal size do not establish hydraulic function or electrical compatibility.
Send both nameplates: include the valve code, coil voltage and frequency, hydraulic symbol and any option suffixes. The valve body and coil may have been changed separately during earlier repairs.
Compare the Two Series
The values below are original Daikin catalogue references [1]. Use them to identify the application, then confirm the offered YHDE configuration, drawing and performance data in the quotation.
| Item | KSO-G02 | KSO-G03 |
|---|---|---|
| Nominal size / mounting | 02 / 1/4 nominal, gasket mount; ISO 4401-03 reference | 03 / 3/8 nominal, gasket mount; ISO 4401-05 reference |
| Maximum flow | 100 L/min | 160 L/min DC; 130 L/min AC |
| Maximum operating pressure | 35 MPa; 25 MPa for 5C, 66C, 51C | 35 MPa; 25 MPa for 5C, 66C, 51C |
| Permissible back pressure | 17.5 MPa | 16 MPa |
| Design number in cited catalogue | 30 | 20 |
| Switching-frequency ceiling | AC/DC: 240/min; rectifier: 120/min; built-in surge killer / DIN connector with lamp: 100/min | AC/DC: 240/min; rectifier: 120/min; built-in surge killer / DIN connector with lamp: 60/min |
Maximum flow is not a recommended operating point at every pressure or spool position. Review the pressure-drop and pressure–flow curves for the selected spool, supply and flow path. Nominal 1/4 and 3/8 designations do not mean threaded ports on the gasket-mounted valve body.
Decode the Complete Model
Reference example: KSO-G02-2CA-30. The example explains the original code; it does not establish current stock or the specification of an unlabelled replacement.
| Field | Meaning / action |
|---|---|
| KSO / G02 | K-series solenoid valve / gasket-mounted size 02. |
| 2 / C | Spool type 2 / spring centered. The 2C symbol is closed center: P, A, B and T blocked in neutral [2]. It is a three-position, four-way arrangement. |
| A after 2C | AC 100 V at 50 Hz; AC 100 or 110 V at 60 Hz in the cited table. Read the actual coil label. |
| Other voltage examples | P = DC 24 V; N = DC 12 V; D = AC 220 V at 50 Hz. Frequency, current and connector options must match. |
| 30 / 20 | G02 / G03 design references respectively; retain the installed design and option suffixes for matching. |
| Additional options | Identify terminal box or DIN connection, lamp, surge suppression, rectifier, fluid/seal compatibility and auxiliary spool code. |
Check the symbol, not a similar-looking code. Yuken codes such as 3C2 or 3C4 are not KSO ordering fields. Spring-centered, spring-offset and detented arrangements have different de-energized behaviour. A closed-center spool does not guarantee leak-free load holding.
Verify the Installation Before Ordering
Hydraulic duty: provide working and peak pressures at P/A/B, T-line pressure, required flow and duty cycle. Check return-line restrictions and common return-manifold pressure.
Manifold fit: compare the actual port locations, bolt threads, locating features, sealing faces and valve envelope. The cited G03 catalogue includes an optional M8 mounting-bolt version; a family label alone cannot confirm fit.
Electrical supply: identify AC/DC, voltage, AC frequency, coil power/current and control-output capacity. Account for AC starting current and the selected suppression or rectifier circuit. Do not assume a PLC output can drive the coil directly.
Environment and fluid: confirm seal material, fluid chemistry, viscosity and temperature. Verify protection for the supplied assembled valve, cable entry and connector; an IP65 reference is not an immersion rating.
Purchase confirmation: request the offered full code, hydraulic symbol, dimensional drawing, supplied accessories and relevant inspection scope before approving the order.
Browse the hydraulic solenoid valve range for other families. Any cross-brand alternative requires a symbol, interface and electrical comparison.
Repair Assessment: Coil, Seal or Complete Valve?
Isolate electrical power, release stored hydraulic pressure and secure the actuator before inspection or disassembly. Record the original wiring and valve orientation.
| Symptom | Checks before selecting parts | Useful quotation information |
|---|---|---|
| No shift / intermittent shift | Verify voltage at the coil under command, wiring and connector condition; investigate contamination, armature movement and hydraulic load. | Coil label, control supply, full valve code and operating conditions. |
| Repeated coil overheating / burnout | Check voltage/frequency, duty, suppression, armature closure and spool movement. Breaker trips alone do not prove spool wear. | Which coil fails, measured supply, timing and photographs. |
| External leakage | Locate the leak at the mounting face, seal or solenoid assembly; inspect mating faces and fasteners. | Leak location, fluid, seal information and mounting drawing. |
| Actuator drift / internal bypass | Check the actuator, load-holding valves and circuit as well as the directional valve; assess spool/bore wear. | Circuit symbol, load, temperature and measured leakage or drift. |
A coil-only change will not repair a damaged bore or contaminated mechanism. Ask for a matched coil or seal assessment, or a complete-valve replacement where appropriate. Confirm service-part compatibility and kit contents before purchase.
Choose a Series and Prepare Your Inquiry
Enter what is actually installed, then choose the request below. The details will be added to the existing inquiry message for your review. Add your email and submit when ready.
Include the hydraulic symbol, installation dimensions or drawing, P/A/B and T pressures, flow, fluid, quantity, destination and required date. Price, availability, lead time and supplied documents depend on the confirmed configuration. If prefill is unavailable, include these details directly in the inquiry form.
Selection and Service Questions
Can I choose G02 or G03 by flow alone?
No. Match the manifold interface, spool function, pressure drop, operating limits and electrical configuration as well. Changing valve size can require a different manifold or subplate.
Does KSO-G02-2CA-30 mean DC24V and two-way operation?
In the cited Daikin code, 2 is the spool type, C means spring centered and A identifies an AC coil. The 2C arrangement is a three-position, four-way closed-center valve. Confirm the complete nameplate and symbol before ordering.
Can every KSO-G03 pass 160 L/min?
The original reference distinguishes 160 L/min for DC from 130 L/min for AC. These are family ceilings; the applicable spool operating envelope and pressure-drop curve still govern selection.
Are all configurations rated to 35 MPa?
No. The original reference gives 25 MPa for 5C, 66C and 51C configurations. Confirm the supplied replacement rating and the permissible T-port pressure separately.
Will a coil-only repair solve a valve that will not shift?
Check supply voltage under load, wiring, driver capacity and the mechanical and hydraulic condition first. A sticking armature or spool can damage a replacement coil again. Match the coil assembly, connector and suppression circuit.
Does closed center guarantee zero actuator drift?
No. A spool valve can have internal leakage. Check the cylinder and the complete load-holding circuit; do not use a directional spool alone as a guaranteed leak-free holding device.
What should I send for a quotation?
Send the complete valve and coil markings, hydraulic symbol, manifold drawing or dimensions, pressure at P/A/B and T, required flow, fluid, quantity and destination. For repair, add symptoms and photographs. Price, availability and lead time require confirmation.
Technical references: [1] Daikin KSO catalogue, G-16–G-31; [2] Daikin solenoid-valve circuit and spool reference, N-35. Original-manufacturer references support identification; the offered replacement specification requires separate confirmation.