• Yuken Type DSG-01 DSG-02 DSG-03 Solenoid Valves For Fydraulic System
  • Yuken Type DSG-01 DSG-02 DSG-03 Solenoid Valves For Fydraulic System
  • Yuken Type DSG-01 DSG-02 DSG-03 Solenoid Valves For Fydraulic System

Yuken Type DSG-01 DSG-02 DSG-03 Solenoid Valves For Fydraulic System

Brand: Yishg

Product origin: China

Delivery time: 10-30day

Supply capacity: 300 Pcs/Day

Model: DSG-01 DSG-02 DSG-03
Max Displacement:120 L/Min-300 L/Min
Max Working Pressure: 25Mpa-35 Mpa
Shaft Speed Range: 100 Cycles/Min-120 Cycles/Min
Control Type: Direct Current Coil
Product Type: Hydraulic Valves
Material: Cast iron

Yuken Type DSG-01 DSG-02 DSG-03 Solenoid Valves For Fydraulic System

DSG Series Solenoid Valves: Selection, Replacement & Service

DSG solenoid operated directional valves switch hydraulic flow to start, stop or reverse an actuator. Select a replacement by the complete valve configuration: mounting interface, spool function, electrical supply and operating limits. The series name alone is not enough to confirm compatibility.

Start with the valve you have. Send the full nameplate code, coil markings and mounting drawing. For a new circuit, provide the required flow, working pressure, tank-line back pressure and desired de-energized function.

Choose a Series or Identify an Existing Valve

DSG-01

Commonly associated with the NG6 / CETOP 3 mounting family. Check the exact drawing, design version and spool symbol.

View DSG-01-3C2-A220-N1-50 example

Request DSG-01 selection
Request DSG-01 repair or parts identification

DSG-02

Identify the actual manufacturer and valve drawing first. Do not infer a mounting size, flow or pressure from the “02” designation.

See the DSG-02 identification checklist

Request DSG-02 selection
Request DSG-02 repair or parts identification

DSG-03

Commonly associated with the NG10 / CETOP 5 mounting family. Confirm port geometry, bolt pattern and available installation space.

View DSG-03-2B2-A220-N1-50 example

Request DSG-03 selection
Request DSG-03 repair or parts identification

Linked product pages show individual configurations, not the full ordering range. Their listed electrical and hydraulic data must be checked against the actual supplied valve before ordering.

DSG-02 identification: provide a readable brand and model label, the hydraulic symbol, mounting-face dimensions, bolt centres, P/T/A/B port locations and coil label. Include the subplate or manifold model if available. A proposed replacement should be confirmed against those details rather than treated as a universal intermediate size.

Read the Complete Ordering Code

A code such as DSG-01-3C2-A220-N1-50 contains more information than the series size. The following is a reading guide for the referenced ordering convention; supplier-specific variants require their own documentation.

Code fields to confirm before selection
FieldMeaning / exampleSelection check
DSG-01 / DSG-03Family and size designationCompare the mounting drawing and envelope. Subplate pipe-thread size is a separate specification.
3C2Three positions, spring centred; the referenced symbol blocks P, T, A and B in the centre position.Read all positions of the hydraulic symbol. A closed centre spool does not provide leak-tight load holding.
3C4 / other spool numbersA different spool functionMatch the actual centre connections and transition behaviour. Do not group every alternative as an “open centre”.
2B / 2DTwo-position spring-offset / detented arrangements in the referenced conventionConfirm which state is retained or restored when power is removed.
A220 / D24Supplier-labelled nominal 220 V AC / 24 V DC optionsVerify the actual coil label, permissible voltage, AC frequency and control-circuit compatibility.
N / N1Plug-in connector / plug-in connector with indicator in the referenced Yuken conventionCheck pin arrangement, earthing, indicator, rectifier or suppression circuit and connector clearance.
50 / 70Design numberThis is not a 50 Hz / 70 Hz frequency code. Use the matching catalogue and drawing.

Check Flow, Pressure and Electrical Limits Together

Catalogue references below explain version differences; they are not declared ratings for a YHDE replacement. Obtain a specification for the exact proposed model before approving an order.

Manufacturer reference data and how to use it
ReferencePublished family informationWhat must be confirmed
Yuken DSG-01, design 70 standard type [1]Up to 100 L/min; maximum operating pressure 35 MPa and T-line pressure 21 MPa. The catalogue compares this with earlier 63 L/min, 31.5 MPa and 16 MPa limits.Do not transfer design-70 figures to a design-50 or supplier replacement. Check the spool-specific flow table and supplied model rating.
Yuken India DSG-03, design 50 standard type [2]Family flow ceiling 120 L/min. This regional catalogue specifies 315 kgf/cm² operating pressure (about 30.9 MPa), with exceptions, and 160 kgf/cm² T-line pressure (about 15.7 MPa).Keep the original units and edition. Check spool exceptions, electrical conditions and actual supplied specifications.
DSG-02 as marked on an existing valveRating and mounting interface require the specific manufacturer's documents.Identify first; request the exact pressure, flow and dimensional data with the quotation.
  • Flow: use the working flow and the pressure-drop curve for the relevant flow path. Cylinder return flow can exceed pump delivery because of the area ratio.

  • Pressure: check P/A/B limits and the separate T-port limit, including return restrictions and pressure transients.

  • Electrical supply: check voltage at the coil during operation, frequency for AC, wiring and the control output's current capability.

  • Fluid and duty: confirm fluid/seal compatibility, viscosity, temperature, cleanliness and permitted switching duty for the actual valve.

Replacement Fit Checklist

  1. Match the hydraulic function. Confirm every spool position, de-energized behaviour and any detent, spring or special option. Use dedicated load-control devices where the circuit requires secure load holding.

  2. Match the mounting face. Verify port positions, bolt centres, seal locations, bolt thread and length, manifold clearances and connector orientation.

  3. Match the electrical assembly. Check coil and solenoid compatibility, connector circuitry and protective-earth requirements. A physically fitting coil is not sufficient proof.

  4. Confirm the operating envelope. Approve the exact model data sheet, pressure-drop information and relevant test documentation before purchase.

Browse hydraulic solenoid valves or request matching from an existing model.

Repair Diagnosis: Coil, Spool or Seal?

Record when the fault occurs, whether it affects one or both directions, and whether it changes with temperature or load. Compare electrical, hydraulic and mechanical evidence before choosing parts.

Before service: isolate electrical and hydraulic energy, release stored pressure and secure any supported load. Qualified personnel should carry out live measurements and controlled recommissioning. Do not remove a coil, connector or valve assembly while it is energized or pressurized.

Symptoms and the appropriate service request
SymptomChecksRepair / replacement route
No shift / indicator onCheck supply at the coil, wiring, output command, coil condition and possible mechanical restriction. An indicator confirms neither magnetic force nor spool travel.Request electrical assembly identification; investigate hydraulic and mechanical causes before replacing the coil.
AC buzz, overheating or repeated coil failureCheck voltage, frequency, duty, ambient temperature and whether the armature can seat. Restricted travel can keep AC current abnormally high.Correct the cause and confirm a matching coil/solenoid assembly. Do not repeatedly energize a stalled assembly.
External oil leakageLocate the leak after cleaning: mounting interface, tube seals, connector area or damaged body. Check sealing-face condition and installation details.Identify the valve-specific seals and compatible material. Replace damaged components; follow the actual assembly and tightening instructions.
Drift, internal leakage or weak motionDistinguish normal spool leakage from wear, wrong centre function, cylinder leakage or load-control faults. Compare results at stated pressure and oil temperature.Consider a matched spool/body assembly or complete valve if worn. External seal replacement cannot repair a worn spool bore.
Intermittent sticking / slow responseCheck contamination, oil condition, temperature, return pressure and mounting distortion as well as the electrical supply.Address system contamination and installation causes. Do not abrasively rework precision spool surfaces without an approved repair procedure.

For parts identification, provide the full valve model and clear details of the failed assembly. A seal or coil must match the specific valve version; a pump cartridge kit is not a directional-valve repair kit. Repair feasibility is confirmed after identification and, where needed, inspection.

Send the Details Needed for a Useful Quotation

Include the full model and manufacturer, coil voltage/frequency, spool symbol, mounting drawing, working pressure, T-line pressure, flow, fluid and quantity. For a fault, add the symptom, test observations and whether you need a coil, seals, repair assessment or complete replacement.

If the inquiry form cannot attach photographs or drawings, mention which files you have and request a suitable way to send them. State the delivery destination and required date; availability and dispatch timing must be confirmed for the exact configuration.

The buttons add a checklist to the inquiry message below. Review and complete it before submitting.

DSG Valve Selection & Repair FAQ

Can DSG-01, DSG-02 and DSG-03 valves be exchanged directly?

Do not select by the DSG prefix alone. Check the exact mounting drawing, port layout, spool symbol, coil specification, pressure and flow limits, and design number. DSG-02 needs identification from its own manufacturer data before a replacement is proposed.

Does every DSG-01 valve have a 100 L/min rating?

No. The Yuken design-70 catalogue lists a 100 L/min family ceiling and compares it with earlier 63 L/min valves. Actual allowable flow depends on the spool and operating conditions. These reference figures do not establish the rating of a YHDE replacement.

What do N, N1 and the final design number mean?

In the referenced Yuken ordering system, N denotes a plug-in connector and N1 adds an indicator light. A final number such as 50 or 70 identifies a design version; it is not the AC frequency. Confirm the supplied valve and connector data.

Can I replace an AC coil with a DC24 coil?

A voltage code alone is insufficient. Confirm the coil, solenoid tube and armature assembly, connector wiring, suppression or rectifier circuit, and control output. Use an approved matching assembly and verify the replacement electrically before commissioning.

Should a leaking valve receive a seal kit or a complete replacement?

First distinguish external leakage from internal leakage. External leakage may involve connector-side tube seals, mounting seals or sealing faces. Internal spool-to-bore wear may require a matched assembly or valve replacement; new external seals will not correct that wear.

What information is needed for selection or repair pricing?

Provide the complete model, nameplate and coil markings, mounting dimensions or drawing, spool symbol, working and tank-line pressures, flow, fluid, symptoms, quantity and destination. Availability, repair scope and lead time are confirmed for the identified configuration.

Related Products6
Product Tag
Get the latest price? We'll respond as soon as possible(within 12 hours)